Translate

2025年12月27日星期六

How to diagnose and troubleshoot the Caterpillar 311B Excavator MID 161 - CID 0168 - FMI 01 fault message?

                                         

                       MID 161 - CID 0168 - FMI 01

 

Caterpillar ET 2025A & 2019C Electronic Technician Diagnostic Software Download and Installation 

 

 This code is generated when PL522 and 523 detect a battery voltage below 11 VDC.

  Test Procedure 1. Check the system voltage at the 70-pin connector of the PL522 and 523 modules.

  Start the engine and run it at high idle for 5 to 10 minutes. Measure the system voltage between the "No Switching Power" and "Ground" contacts. Pin 52 is the "No Switching Power" terminal, and pin 65 is the "Ground" terminal.

  Expected Results: 24 VDC system voltage: 27 VDC to 29 VDC. 12 VDC system voltage: 13 VDC to 15 VDC. Results:

  • Normal - Voltage is correct. Clear this diagnostic code and check for any other diagnostic codes. Stop

 • Abnormal - The voltage is abnormal. Proceed to Test Step 2. 

 Test Step 2. Check the alternator.

 Run the engine at high idle for 5 to 10 minutes. Measure the voltage output at the battery terminals.

 12.2021 Caterpillar ECM ECU Flash Files Full Set Download

 Expected Result: For a 24 VDC system, the voltage range should be 27 VDC to 29 VDC. For a 12 VDC system, the voltage range should be 13 VDC to 15 VDC.

  Result: 

• Normal - The voltage is correct. Proceed to Test Step 3

. • Abnormal - The voltage is abnormal.

  Repair: Repair or replace the alternator.

 

  Stop Test Step 3. Check the battery voltage.

  Turn the ignition switch to the off position. Measure the voltage at the battery terminals. Always wear appropriate personal protective equipment. Expected Result: The voltage of a 12 VDC system should be between 12 VDC and 15 VDC. The voltage of a 24 VDC system should be between 24 VDC and 27 VDC.

  Result: • Normal - Voltage between 12 VDC and 15 VDC, or between 24 VDC and 27 VDC.

  Repair: PL522 or 523 may be faulty. Recheck the system before replacing PL522 or 523. PL522 or 523 are rarely the root cause of failure. Please refer to System Operation, Troubleshooting and Repair, Testing and Adjustment, "Electronic Control Module (ECM) - Replacement". After replacing PL522 or 523, recheck the system and check the status of diagnostic codes.

 Stop • Abnormal - Voltage is not between 12 VDC and 15 VDC, or voltage is not between 24 VDC and 27 VDC.

  Repair: Refer to the specific manual, REHS0354, "Charging System Troubleshooting and Repair". If the situation does not improve, PL522 or 523 may be faulty. Recheck the system before replacing PL522 or 523. PL522 or 523 are rarely the root cause of the problem. Refer to System Operation, Troubleshooting and Repair, Testing and Adjustment, "Electronic Control Module (ECM) - Replacement". After replacing PL522 or 523, recheck the system and check the status of diagnostic codes.

 CAT Comm Adapter 3 478-0235 Diagnostics for Caterpillar

 

 

 

 

 

 

 

 

 

 

How to diagnose and troubleshoot the Caterpillar 311B Excavator MID 161 - CID 0168 - FMI 01 fault message?

                                                                 MID   161 - CID   0168 -   FMI   01   Caterpillar ET 2025A & 2019C Elec...